55 … AA frame — 1535 nm C-series 6 km and 8 km modules (2 scanned manuals)

Read from scanned manuals · page-image checked · example checksums re-derived · page citations kept

The host sends `55 | command + payload + XOR checksum (4 bytes) | AA`. The module answers with a 15-byte frame headed by AA and terminated by 55; the checksum covers bytes 2–13. Query replies start with CC.

Frame layout

命令帧 6 字节:0x55 | 命令码+参数+校验(4 字节)| 0xAA;校验 = 第 2–4 字节 XOR。应答 15 字节:0xAA | 目标数 | 首目标距离高/低/小数 | 末目标距离高/低/小数 | 状态字节 | 激光发射计数(4 字节)| 校验(第 2–13 字节 XOR)| 0x55;查询应答帧头 0xCC。UART-TTL,115200 bps(出厂)/57600/38400/9600,8N1。源:手册 p4–p5(扫描件 OCR,170dpi 目检)。

Command set

CodeFunctionSendReplyNotes / page
0xF2Single-shot ranging55 F2 00 00 ?? AA见 p5 Table 3/5原文该行只印 3 字节(0xF2 0x00 0x00),未给校验字节;不推断
0xF31 Hz ranging55 F3 01 00 F2 AA见 p5 Table 3/5校验 = 字节 2–4 XOR
0xF32 Hz ranging55 F3 03 00 F0 AA见 p5 Table 3/5校验 = 字节 2–4 XOR
0xF33 Hz ranging55 F3 04 00 F7 AA见 p5 Table 3/5校验 = 字节 2–4 XOR
0xF34 Hz ranging55 F3 05 00 F6 AA见 p5 Table 3/5校验 = 字节 2–4 XOR
0xF35 Hz ranging55 F3 02 00 F1 AA见 p5 Table 3/5校验 = 字节 2–4 XOR
0xF310 Hz ranging55 F3 06 00 F5 AA见 p5 Table 3/5校验 = 字节 2–4 XOR
0xF3Stop ranging55 F3 00 00 F3 AA见 p5 Table 3/5校验 = 字节 2–4 XOR
0xF6Baud-rate setting55 F6 XX XX CHK AA见 p5 Table 3/5XX = 波特率/100(十六进制);XX 为字节 2–4 XOR
0xF0Self-test command55 F0 00 00 ?? AA见 p5 Table 3/5原文只印 3 字节,未给校验字节;不推断
0xF8Status query55 F8 00 00 ?? AA见 p5 Table 3/5原文只印 3 字节,未给校验字节;不推断
0xF4Range-gate setting55 F4 XX XX CHK AA见 p5 Table 3/5XX = 门限距离;CHK = 字节 2–4 XOR

Timing and rates

p3 · Baud 115200 bps (factory) / 57600 / 38400 / 9600; 8N1; LSB first.

Status codes and errors

p5 · 状态字节(byte 9):0xF2 单次 / 0xF3 1Hz / 0xF6 2Hz / 0xF7 3Hz / 0xF8 4Hz / 0xF4 5Hz / 0xFA 10Hz / 0xF5 停止;查询数据 byte 4:0x00 默认 / 0x03 自检发射正常 / 0xFF 异常。

What the source does not state

Where a manual prints an incomplete reply (for example only 55 for the LD constant-on acknowledgement), this page reproduces that and stops — it does not pad the frame. Anything not printed in the manual is absent here on purpose.

These manuals are scans with no text layer. The frame and command bytes above were read from 300 dpi page images (then re-rendered at 170 dpi for a second look), the printed example frames were re-checked against the checksum rule, and the layout is identical across the 2 manuals in this family. The raw OCR text stays offline; only what the page images show is published.

Models covered by this page

Source documents

Transcription method: these PDFs have no text layer, so this page was built from OCR plus a 170 dpi re-read of the page image. Every example frame was re-derived from the checksum rule the manual prints; a byte that is not legible in the page image is not published.

Related